Abstract

Environmental qualification testing was performed on a modified Limitorque torque switch for the torque switch safety functions in the Limitorque type SMB actuators located inside and outside containment in a nuclear power plant. The torque switch specimen was installed in a Limitorque SMB-1 electric actuator mounted on an 8” Velan gate valve and operated with a customized programmable logic controller to allow normal torque switch behaviour to be observed. The present paper describes the qualification testing performed. The modified torque switch was aged to a 30-year service life at the normal service conditions for both inside and outside containment. Aging included radiation, thermal and cycle aging. A seismic test and then a combined Loss of Coolant Accident (LOCA) and Main Steam Line Break (MSLB) steam accident simulation were followed. After each stage of aging, functional tests were done to confirm normal insulation resistance, normal contact resistance and normal operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.