Abstract

The fate of trace elements in a combustion power plant equipped with a wet limestone flue gas desulphurisation (FGD) installation was studied in order to evaluate its emission abatement capacity. With this aim representative samples of feed coal, boiler slag, fly ash, limestone, FGD gypsum and FGD process water and wastewater were analysed for major and trace elements using the following techniques: inductively coupled plasma-mass spectrometry (ICP-MS), inductively coupled plasma-atomic emission spectrometry (ICP-AES), ion chromatography (IC), ion selective electrode (ISE) and atomic absorption spectroscopy (AAS). Mass balances were established allowing to determine the element partitioning behaviour. It was found that, together with S, Hg, Cl, F, Se and As were those elements entering in the FGD plant primarily as gaseous species. The abatement capacity of the FGD plant for such elements offered values ranged from 96% to 100% for As, Cl, F, S and Se, and about 60% for Hg. The environmental characterisation of combustion by-products (boiler slag, fly ash and FGD gypsum) were also established according to the Council Decision 2003/33/EC on waste disposal. To this end, water leaching tests (EN-12457-4) were performed, analysing the elements with environmental concern by means of the aforementioned techniques. According to the leaching behaviour of combustion by-products studied, these could be disposed of in landfills for non-hazardous wastes.