Abstract

Urbanization and industrial development intensify water utilization and wastewater generation. The efficiency of wastewater treatment systems varies and depends on system design and wastewater condition. The research aims to examine seven existing centralized municipal wastewater treatment plants (WWTPs) in Bangkok to discover which system configuration yields the best environmental and economic performance. The degree of environmental impact and operational costs from different system designs were investigated to help select future wastewater treatment systems. Life cycle assessment (LCA) has been conducted to evaluate environmental impacts from centralized municipal wastewater treatment systems. Life cycle impact assessment method based on endpoint modeling (LIME) was applied, with three major potential environmental impact categories including eutrophication, global warming, and acidification. All seven centralized municipal WWTPs in Bangkok were investigated as case studies. The system configurations are classified into five types of activated sludge (AS) systems. The contribution of impacts from individual processes in each type of AS system was analyzed. The methodology covered major on-site and off-site operational processes excluding construction and maintenance phases. Average annual data were calculated to develop an inventory dataset. JEMAI-Pro software was utilized in this study to analyze the life cycle impact of the systems. The level of environmental impact from a WWTP depends on the configuration of the AS system. The highest potential environmental impact from a municipal WWTP is eutrophication, which is obviously affected by ammonium and phosphorous discharges into water bodies. The vertical loop reactor activated sludge (VLRAS) system yielded the best treatment performance among the five AS sub-systems. The consumption of electricity used to operate the system contributed significantly to global warming potential and correlated considerably with operating costs. Comparing among three system sizes, the large-scale WWTP revealed inefficient electricity consumption, whereas the medium plant provided better performance in chemical use and operating costs. Centralized municipal WWTPs with capacities ranging from 10 to 350 × 103 m3/day were evaluated with respect to environmental performance and costs during the operating phase. Among all case studies, a medium-scale WWTP with a VLRAS system offered the best operating performance in terms of low environmental impact, resource consumption, and cost. To enhance WWTP management, it is vital to improve the efficiency of electricity consumption in primary and secondary treatment processes and increase wastewater collection efficiency to maximize the plant operating capacity and minimize overall environmental impacts.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.