Abstract
As part of the Partners in School Asthma Management Program, environmental data were collected from 385 rooms in 60 elementary schools in southeast Texas, using an Environmental Observation Checklist and a Q-TRAK Indoor Air Quality Monitor. Dust samples for allergen analysis were collected from floors, carpets, and area rugs in 80 classrooms in a subset of 20 schools. CO2 levels > 1,000 ppm were found in 86% of rooms; 69% had indoor humidity above recommended levels. Der p I dust mite allergen levels > 2,000 ng/g were present in 20% of rooms, but only 2.5% of rooms had Der f I mite allergen levels exceeding recommended tolerances. Detectable levels of cockroach allergen (Bla g II) were found in all schools (median 5.5 ng/g), with 10% of rooms over the recommended threshold. Almost two-thirds of classrooms had mold spore counts > 10,000 col/g (median, 14,400 col/g; range, 2,000-52,000 col/g).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Journal of School Health
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.