Abstract

The AOAC Use-Dilution methods do not provide procedures to enumerate the test microbe on stainless steel carriers (penicylinders) or guidance on the expected target populations of the test microbe (i.e., a performance standard). This report describes the procedures used by the U.S. Environmental Protection Agency to enumerate the test microbe (carrier counts) associated with conducting the Use-Dilution method with Staphylococcus aureus (Method 955.15) and Pseudomonas aeruginosa (Method 964.02) and the examination of historical data. The carrier count procedure involves the random selection of carriers, shearing bacterial cells from the carrier surface through sonication, and plating of serially diluted inoculum on trypticase soy agar. For each Use-Dilution test conducted, the official AOAC method was strictly followed for carrier preparation, culture initiation, test culture preparation, and carrier inoculation steps. Carrier count data from 78 Use-Dilution tests conducted over a 6-year period were compiled and analyzed. A mean carrier count of 6.6 logs (approximately 4.0 x 10(6) colony-forming units/carrier) was calculated for both S. aureus and P. aeruginosa. Of the mean values, 95% fell within +/- 2 repeatability standard deviations. The enumeration procedure and target carrier counts are desirable for standardizing the Use-Dilution methods, increasing their reproducibility, and ensuring the quality of the data.