Abstract
On the basis of the first and second laws of thermodynamics, the general expression of the number of entropy generation units of three-fluid heat exchangers with three thermal communications was derived. The effect of several non-dimensional design parameters on the number of entropy generation units of three-fluid heat exchangers was thoroughly discussed. Furthermore, the detailed comparisons of results have been given for the arrangement of the parallel flow and the counter flow. It is shown that the variation tendencies of the number of entropy generation units with the ratio of the thermal resistances, ratio of the thermal capacities, and number of heat transfer units for the parallel-flow arrangement are different from those of the counter-flow arrangement. There exists an extremum of the number of entropy generation units for the counter-flow arrangement. In addition, the entropy generation for the counter flow is mostly smaller than that of the parallel flow under the same conditions.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.