Abstract

This article examines various uncertainties relating to calculation methods for the balcony spill plume. The approach of physical scale modeling is used in the analysis. Comparisons are made between experimental results and predictions made using these calculation methods. This work has demonstrated that the presence of a downstand from the soffit at the spill edge of a compartment opening appears to have little effect on the entrainment of air into the subsequent spill plume. A simplified spill plume formula has also been developed to predict the mass flow rate of gases, which inherently includes entrainment of air into the free ends.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.