Abstract
Isobaric enthalpy increment measurements have been made on liquid ethane. The temperature and pressure ranges covered by the measurements are (146.0 to 256.2) K and (1.16 to 5.07) MPa. The measurements have an average standard uncertainty of ±0.07 kJ·kg −1or 0.21 per cent of the enthalpy increment. A new flow calorimeter test loop that avoids the two-phase region is described. The flow calorimeter used is of the electrically heated type.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.