Abstract

The objectives of this study were to evaluate the relationship between residual feed intake (RFI; g/d) and enteric methane (CH) production (g/kg DM) and to compare CH and carbon dioxide (CO) emissions measured using respiration chambers (RC) and the GreenFeed emission monitoring (GEM) system (C-Lock Inc., Rapid City, SD). A total of 98 crossbred replacement heifers were group housed in 2 pens and fed barley silage ad libitum and their individual feed intakes were recorded by 16 automated feeding bunks (GrowSafe, Airdrie, AB, Canada) for a period of 72 d to determine their phenotypic RFI. Heifers were ranked on the basis of phenotypic RFI, and 16 heifers (8 with low RFI and 8 with high RFI) were randomly selected for enteric CH and CO emissions measurement. Enteric CH and CO emissions of individual animals were measured over two 25-d periods using RC (2 d/period) and GEM systems (all days when not in chambers). During gas measurements metabolic BW tended to be greater ( ≤ 0.09) for high-RFI heifers but ADG tended ( = 0.09) to be greater for low-RFI heifers. As expected, high-RFI heifers consumed 6.9% more feed ( = 0.03) compared to their more efficient counterparts (7.1 vs. 6.6 kg DM/d). Average CH emissions were 202 and 222 g/d ( = 0.02) with the GEM system and 156 and 164 g/d ( = 0.40) with RC for the low- and high-RFI heifers, respectively. When adjusted for feed intake, CH yield (g/kg DMI) was similar for high- and low-RFI heifers (GEM: 27.7 and 28.5, = 0.25; RC: 26.5 and 26.5, = 0.99). However, CH yield differed between the 2 measurement techniques only for the high-RFI group ( = 0.01). Estimates of CO yield (g/kg DMI) also differed between the 2 techniques ( ≤ 0.03). Our study found that high- and low-efficiency cattle produce similar CH yield but different daily CH emissions. The 2 measurement techniques differ in estimating CH and CO emissions, partially because of differences in conditions (lower feed intakes of cattle while in chambers, fewer days measured in chambers) during measurement. We conclude that when intake of animals is known, the GEM system offers a robust and accurate means of estimating CH emissions from animals under field conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.