Abstract

To investigate the validity of the Interventional Ultrasound Skills Evaluation (IUSE) tool for assessment of procedural competence in ultrasound-guided procedures in a clinical environment, including a pass/fail score. Novices and experienced radiologists were recruited from four hospitals and were observed and assessed while performing ultrasound-guided procedures. Performances were assessed using the IUSE tool by two independent raters. Validity evidence was gathered in accordance with Messick's framework: response process was ensured by standardisation of written rater instructions. Internal structure was explored using Cronbach's alpha for internal consistency reliability; inter-rater reliability was calculated as Pearson's r independently across all ratings, and test-retest reliability was reported using Cronbach's alpha. Relationship to other variables was investigated by comparing performances of the participants in each group. Consequences evidence was explored by calculating a pass/fail standard using the contrasting groups method. Six novices and twelve experienced radiologists were enrolled. The IUSE tool had high internal consistency (Cronbach's alpha = 0.96, high inter-rater reliability (Pearson's r =0.95), and high test-retest reliability (Cronbach's alpha = 0.98), and the mean score was 33.28 for novices and 59.25 for experienced with a highly significant difference (p value < 0.001). The pass/fail score was set at 55 resulting in no false positives or false negatives. Validity evidence from multiple sources supports the use of the IUSE tool for assessment of competence in ultrasound-guided procedures in a clinical environment and its use in high-stakes assessment such as certification. A credible pass/fail criterion was established to inform decision-making. • A multi-site validity investigation established that the Interventional Ultrasound Skills Evaluation (IUSE) tool can be used to assess procedural competence in ultrasound-guided procedures. • Validity evidence was gathered according to Messick's framework validity from the following sources: response process, internal structure, relationship to other variables, and consequences evidence. • The IUSE tool can be used for both formative and summative assessment, and a credible pass/fail score was established to help inform decision-making such as certification.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call