Abstract

This study presents a method to enhance the contrast and luminosity of fundus images with boundary reflection. In this work, 100 retina images taken from online databases are utilized to test the performance of the proposed method. First, the red, green and blue channels are read and stored in separate arrays. Then, the area of the eye also called the region of interest (ROI) is located by thresholding. Next, the ratios of R to G and B to G at every pixel in the ROI are calculated and stored along with copies of the R, G and B channels. Then, the RGB channels are subjected to average filtering using a 3 × 3 mask to smoothen the RGB values of pixels, especially along the border of the ROI. In the background brightness estimation stage, the ROI of the three channels is filtered by binomial filters (BFs). This step creates a background brightness (BB) surface of the eye region by levelling the foreground objects like blood vessels, fundi, optic discs and blood spots, thus allowing the estimation of the background illumination. In the next stage, using the BB, the luminosity of the ROI is equalized so that all pixels will have the same background brightness. This is followed by a contrast adjustment of the ROI using CLAHE. Afterward, details of the adjusted green channel are enhanced using information from the adjusted red and blue channels. In the color correction stage, the intensities of pixels in the red and blue channels are adjusted according to their original ratios to the green channel before the three channels are reunited. The resulting color image resembles the original one in color distribution and tone but shows marked improvement in luminosity and contrast. The effectiveness of the approach is tested on the test images and enhancement is noticeable visually and quantitatively in greyscale and color. On average, this method manages to increase the contrast and luminosity of the images. The proposed method was implemented using MATLAB R2021b on an AMD 5900HS processor and the average execution time was less than 10 s. The performance of the filter is compared to those of two other filters and it shows better results. This technique can be a useful tool for ophthalmologists who perform diagnoses on the eyes of diabetic patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.