Abstract
ABSTRACTThis article investigates the use of photon attenuating inclusions (PAI) for enhancing radiographic imaging of cementitious materials in composite structures. By targeting characteristic high attenuation regions in the photon energy spectrum, PAI can improve void detection in the parent material by increasing contrast in radiographic images. Radiographic imaging of cementitious grout specimens with 5% and 15% weight fractions of candidate PAI materials (Fe, BaCO3, BaSO4) was performed to characterize X-ray attenuation. Virtual radiography simulations were then conducted to evaluate the application of PAI to grout void detection in post-tensioned concrete construction. The simulations demonstrate that grout void detection is most effective when the high energy region of the emission spectrum is near the K-edge of the PAI material.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.