Abstract

Force plates have been widely used in various scientific fields to measure ground reaction forces experienced by animals and humans. A force plate that incorporates mechanical springs and non-contact displacement sensors offers the advantages of facilely modifying its shape and performance. However, the design protocol was limited to adjusting the plate size and spring constants of the springs supporting the plate at the four corners. Herein, we propose an optimization method for determining the spring constant distribution of a force plate. The proposed design enables the use of simulations to optimize the mechanical properties of the force plate, such as resonant frequency and error due to position. The experimental results demonstrated that the resonant frequency of the fabricated force plate was 133 Hz and the error due to position was within ±5 %. These results confirm that the proposed force plate can be effectively adjusted through optimization.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.