Abstract

Feasibility of enhancing nutrient removal in municipal sewage plant by using iron shavings in conventional biological treatment reactor was evaluated. Results of 209-days bench-scale test indicate that this method is feasible in practice. Compared to control test, TN and TP removal was increased 8.72 % and 57.83 %, respectively,by adding 400 g iron shavings in 75 L biological reactor. Effluent TP concentration could attain level 1A (0.5 mg L-1) of China's urban sewage treatment plants discharge standards; Total iron concentration in effluent was 0.249 mg L-1 and iron consumption rate was 762.7 mg d-1 during stable period. The enhancing effect of iron shaving on nutrient removal is easy to achieve and low-cost. It is worth investigating in a deep-going way.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.