Abstract
The first-generation high frequency switching megawatt-class High Voltage Converter Modulators (HVCM) developed by Los Alamos National Laboratory for the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory have been installed and are now operational. Each unit is capable of delivering pulses up to 11 MW peak, 1 MW average power at voltages up to 140 kV to drive klystron(s) rated up to 5 MW. To date, three variations of the basic design have been installed, each optimized to deliver power to a specific klystron load configuration. Design improvements, with the primary intention of improving system reliability and availability, have been under development since the initial installation of the HVCM units. This paper will examine HVCM reliability studies, reliability operational data, and modifications and improvements performed to increase the overall system availability. We will also discuss system enhancements aimed at improving the ease of operation and providing for additional equipment protection features.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.