Abstract

This paper investigates the improved switching-table-based direct torque control strategies (ST-DTC) for dual three-phase permanent magnet synchronous machine drives. The classical ST-DTC scheme for dual three-phase drives is usually seriously penalized by significant current harmonics, which cause large losses and reduce the efficiency of the drive system. Hence, a modified switching table consisting of 12 new synthetic voltage vectors is proposed. With this new switching table, not only the variables relating to the torque production are well controlled, but also the variables contributing to the current harmonics are eliminated successfully within one sampling period. Furthermore, a simple modified torque regulator is proposed to reduce the torque ripple and the steady-state error of torque which is usually observed in the real-time system. The switching sequence which is most suitable for the implementation of the real-time system has been proposed to minimize the computation burden. The proposed strategy only changes the switching table and torque regulator without any major modifications, and hence, the merits of the classical direct torque control, i.e., simple structure and good robustness, are still preserved. The experimental results validate the effectiveness of the proposed strategy.