Abstract
This paper presents the results obtained from an experimental study conducted to investigate the effect of shrinkage reducing admixture (SRA) and steel fiber addition on the performance properties of lightweight aggregate concrete (LWAC). Total of seven LWAC mixes with SRA or steel fibers were produced at the same water-cement ratio using cold-bonded fly ash coarse aggregates. The percentage of steel fiber volume fractions used in the mixes was 0.25, 0.75 and 1.25. The amount of SRA used in the mixes was 0.75%, 1.5% and 3 % by weight of cement. Ring type specimens were used for the restrained shrinkage cracking test. At the same time, free shrinkage and weight loss of LWACs were measured. Moreover, the compressive and split tensile strength tests were undertaken. The results indicated that the use of steel fibers has little effect on compressive strength but it improves the split tensile strength. The addition of SRA decreases compressive strength without affecting tensile strength. Moreover, the utilization of steel fiber or SRA extends the cracking time and reduces the crack width of LWAC resulting in finer cracks associated with lower free shrinkage.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.