Abstract

ABSTRACT The present paper presents a deep study on the effects of inductor parameters, such as core material, mechanical construction, DC resistance, quality factor and series resistance on the design, implementation and operation of self-lift SEPIC converters. The proposed DC-DC 5/22 volts converter has been designed to operate in the discontinuous conduction mode (DCM), as a result of which the switch node ringing appeared. It was noticed that the ringing parameters varied depending on the inductor type, where VP-P values were 6, 8.4, 8.8 and 9.2 volts for four different inductors. So, it is clear from the obtained results that, the output voltage (VO) value ranged from 17.3 up to 21.5 volts duo to using toroid choke inductor with DC resistance 148 mΩ and bobbin inductor with DC resistance 91 mΩ, respectively. On the other hand, the snubber circuit had been used to reduce the switch node ringing dependent on the ringing frequency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.