Abstract

A simple, rapid, and convenient method for the determination of neomycin based on the ion association method was proposed. In Britton–Robinson buffer solution, neomycin could react with Congo red to form an ionic association, which in turn reacted with dodecyl trimethyl ammonium bromide to form a ternary ionic association. The three were combined in a 1 : 1 : 1 ratio, which significantly enhanced the resonant Rayleigh scattering intensity at 468 nm. The obtained resonant Rayleigh scattering sensor showed a linear relationship with neomycin in the range of 0.07∼1 μg·mL−1. The limit of detection was 0.02 μg·mL−1, and the limit of quantification was 0.037 μg·mL−1. The experimental conditions were optimized. The method was verified based on the ICH rule. The established method could be applied to the analysis of the acceptable recovery rate of neomycin in powdered veterinary drugs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.