Abstract

Medical devices with embedded highly miniaturized microsystems are used as implants in the human body or as non-invasive devices for sensor applications outside the body. Those devices bear quite a lot of economic opportunities but they also do offer unique challenges compared to consumer or automotive applications. Medical applications need to provide biocompatibility, highest miniaturization, rough treatment, autoclave sterilization and harsh environment e.g. humidity, wax, dust, blood or urine to be applicable. And microelectronics packaging needs to protect the functional elements of the microsystem against these rigid conditions. And, with a different set of media, packaging needs to fulfill the same task for automotive applications, where a growing number of control units and sensor systems under the hood in the transmission oil or petrol can be found. For both markets low cost packaging concepts with high media resistivity is needed. Polymer materials - mainly epoxy resins - are widely used in microelectronics packaging. They are established in microsystem manufacturing, for adhesives as die attach glues or for encapsulants as molding compounds, glob tops or underfill materials. Low cost and mass production capabilities are the main advantages of these materials. But like all polymers they cannot provide a hermetical sealing due to their permeability properties. The susceptibility to diffusion of liquids and gases through the polymer and along the interfaces is a drawback for polymer materials in general, as water or other media inside a microelectronic package might lead to softening of the material and to a decreasing adhesive strength and resulting delaminations close to solder bumps or wire bonds reducing package reliability by decreasing the package structural integrity. Therefore, plastic packaging materials with enhanced humidity resistance allowing the manufacturing of miniaturized microsystems for demanding applications as e.g. medical devices would increase package reliability during assembly and lifetime ideally without cost increase and with no changes in processing. As filler particles have an important influence on the final material properties of microelectronic encapsulants, they are well suited for material modifications. Typically micro-sized silica particles are incorporated into the polymer matrix as the thermo-mechanical properties could be well adapted to reliable packaging demands. However, there are a lot of nano-and micro-sized filler particles with potential to enhance the humidity barrier properties of encapsulants. Working principles of these particles may range from large surface impact of nano-particles, barrier functionality due to stacked layer formation (nano-clays), highly hydrophobic particle surface and molecular water catcher function. Micro- and nano-sized SiO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> , bentonite, zeolites, Al <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> , carbon black and carbon nano tubes have been selected for a systematic study. To evaluate the potential of such additives concerning moisture resistance particles are mixed with a microelectronic grade epoxy resin. Neat particles as well as formulations are characterized regarding their water absorption, diffusion and barrier properties. Additionally multi-layer encapsulants with highest humidity barrier properties are introduced. Here, the mechanical or thermo-mechanical functionality is separated from humidity barrier characteristic. Polymer layers are processed wet in wet resulting in a homogeneous encapsulation with gradient material properties. Different methods for characterization of the diffusion properties close to microelectronics application have been developed and applied for material analysis. The pros and cons of simple weight measuring for absorption testing, sorption analysis, TGA desorption measuring, dielectric spectroscopy and encapsulated humidity sensors are presented and discussed along testing results with formulations with the different filler particles. The results of the measurement allow a modeling of the diffusion behavior of the characterized encapsulants and therewith a forecast on the later reliability of the overall system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.