Abstract

A novel method to increase the adhesion strength of pure carbon coatings on Ti-6Al-4V biomaterials is reported. In the early stage of the experiment, ion implantation of carbon was carried out by metal vapour vacuum arc (MEVVA) in order to create a gradient composition interlayer in the Ti-6Al-4V substrate for subsequent coating depositions. The pure carbon coatings were deposited in a closed-field unbalanced magnetron sputtering system. It was found that the coatings prepared on the carbon-implanted substrates could provide a significant enhancement of adhesion strength, impact and wear resistance. The greatly increased performance could be explained by the increase in hardness of the carbon-implanted substrate and the formation of Ti–C bonds.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.