Abstract

An approach to improve the side-coupling ratio of the macro-bend polymer optical fiber (POF) coupler is proposed in this paper. Two naked POFs are twisted and twined around a cylinder to achieve continuous liquid level sensing. Through filling the gap between the two twisted POFs with UV optical cement, both the sensitivity and the measurement range are increased substantially. The reversibility is also improved since the gap is eliminated, and little liquid can exist in the structure with the liquid level decreasing. The design turns out to be a good method to enhance the performance, and could also be applied in the displacement or stress sensing field.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.