Abstract

PANI/chitosan composite and a ternary composite comprising of PANI, chitosan, and reduced graphene oxide have been successfully synthesised and characterised using FTIR and UV-VIS spectroscopy. Optical constants of the composites were extracted from the UV-VIS spectra. The extracted parameters were applied in the simulation of a surface plasmon resonance (SPR) biosensor functionalised with PANI/chitosan and ternary composites. The aim was to explore the applicability of the composite-based SPR sensor in the detection of low-concentration acetone vapour within the range of 1.8 ppm–5.0 ppm for diabetes monitoring and screening. The functionalization of the SPR sensor with the PANI/chitosan and the ternary composites shows promising application of the sensor in the detection of acetone vapour at a low concentration down to less than 0.5 ppm. The maximum sensitivity values of about 60 and 180 degree/refractive index change were observed for PANI/chitosan and ternary composite sensing layers, respectively, in comparison with the bare gold-based SPR which shows no response up to 10 ppm concentration of acetone vapour in air. In addition, the two sensing layers show good selectivity to acetone vapour compared to ethanol, methanol, and ammonia. The response in the case of ternary composite shows better linearity with a correlation coefficient of 1.0 compared to PANI/chitosan- and gold-based SPR layers with 0.9999 and 0.9997, respectively.

Highlights

  • The interaction between light waves and conduction electrons at the interface of metal and dielectric media produces quanta of longitudinal surface waves

  • All the characteristics peaks for PANI, chitosan, and reduced graphene oxide (RGO) were observed as summarised in Tables 1 and 2 for Fourier transform infrared spectroscopy (FTIR) and ultra violet-visible spectroscopy (UV-VIS), respectively

  • This work presents the application of PANI/chitosan composite and a ternary composite comprising of PANI, chitosan, and reduced graphene oxide in the Surface plasmon resonance (SPR) sensing of acetone vapour for the monitoring and screening of diabetes using mathematical modeling and simulation

Read more

Summary

Introduction

The interaction between light waves and conduction electrons at the interface of metal and dielectric media produces quanta of longitudinal surface waves. The waves are called surface plasmons and are confined at a smaller wavelength along the surface of the metal (plasmonic material) in contact with the dielectric interface [1,2,3]. The incident angle of the light at which nearly complete attenuation of the reflected light occurs is called the SPR angle, and it is a function of the optical properties of the metal, dielectric medium, and any adsorbate on the metal. This dependency is exploited in Journal of Sensors. SPR-based sensors feature high sensitivity, real-time noninvasive measurement, label-free measurement, and nonrequirement of electrodes [1, 4]

Objectives
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.