Abstract

The voltammetric behaviour of 4-nitroso-N,N–dimethylaniline (4-NDMA) was investigated on plain glassy carbon electrode (GCE) and multi-walled carbon nanotube modified GCE (MWCNT/GCE) using cyclic voltammetry. Effects of pH, scan rate and concentration were studied. The surface morphology of the modified electrode in the absence and presence of 4-NDMA molecules was characterized by atomic force microscope (AFM). A systematic study on the variation of experimental parameters with differential pulse stripping voltammetry (DPSV) was carried out and the optimized experimental conditions were arrived. MWCNT/GCE performed well compared with the plain GCE system and the limit of detection (LOD) was found to be 7.5 ng/mL 0.1056 ng/mL for 4-NDMA on plain GCE and MWCNT/GCE respectively.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call