Abstract

Modern heritage buildings designed in the 1950s and 1960s often feature poor seismic performance capacities and may require significant retrofit interventions. A representative case study in Florence, i.e., the edifice housing the Automobile Club Headquarters, is examined here. The building was designed in 1959 with an articulated reinforced concrete structure and presents some enterprising solutions for the time, including suspended floors accommodating large glazed curtain wall façades in the main halls. The original design documentation was collected with accurate record research and checked with detailed on-site surveys. Based on the information gained on the structural system by this preliminary investigation, a time-history assessment analysis was carried out. Remarkable strength deficiencies in most members and severe pounding conditions between the two constituting wings, which are separated by a narrow technical gap, were found. As a result, a base isolation retrofit hypothesis is proposed in order to improve the seismic response capacities of the building without altering its elegant architectural appearance, being characterized by large free internal spaces and well-balanced proportions of the main structural members. A substantial performance improvement is obtained thanks to this rehabilitation strategy, as assessed by the achievement of non-pounding response conditions and safe stress states for all members up to the maximum considered normative earthquake level. Furthermore, the very low peak inter-storey drifts evaluated in retrofitted conditions help in preventing damage to the glazed façades and the remaining drift-sensitive non-structural components.

Highlights

  • Is a country with an architectural heritage of inestimable value

  • This study is aimed at providing new contributions to this topic, by proposing a base isolation retrofit strategy capable of substantially improving the seismic performance of modern heritage buildings while not causing intrusion to their interiors and preserving their fine architectural appearance

  • In order to substantially improve the seismic performance of the structure without altering its architectural appearance, a base isolation retrofit hypothesis is developed here, as a preliminary study to a possible application on the building to be carried out in the near future

Read more

Summary

Introduction

Is a country with an architectural heritage of inestimable value This applies to several buildings designed by eminent architects and structural engineers and erected in the 1950s and 1960s, some of which are included in modern heritage listings. This study is aimed at providing new contributions to this topic, by proposing a base isolation retrofit strategy capable of substantially improving the seismic performance of modern heritage buildings while not causing intrusion to their interiors and preserving their fine architectural appearance. In order to substantially improve the seismic performance of the structure without altering its architectural appearance, a base isolation retrofit hypothesis is developed here, as a preliminary study to a possible application on the building to be carried out in the near future. The architectural and structural characteristics of the building, the results of the time-history assessment analyses in current conditions, the design of the isolation system and the seismic performance attained in retrofitted configuration are discussed

Structural Characteristics of the Building
Vertical section of the building denoted as
Design drawing a double-end cantilevered beam situated great hall
Seismic Assessment Analysis in Current Condition
Multi-linear
Modal Analysis
Time-History and Seismic Performance Assessment Analysis
Base Isolation Retrofit Hypothesis
Time-History and Seismic Performance Verification Analysis
Time-History
19. The average width in termsmeet of force
Findings
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.