Abstract

Total ionizing dose effects are investigated in input/output transistors that are fabricated by using a commercial 0.18 μm bulk process. An enhanced radiation-induced narrow channel effect is demonstrated in N-type metal-oxide semiconductor (NMOS) and P-type metal-oxide semiconductor (PMOS) transistors, leading to a significant threshold voltage shift which may compromise circuit operations. Calculations using a code dedicated to radiation-induced charge trapping in oxides show that the radiation-induced positive charge trapping in trench oxides leads to the modifications of the electrical characteristics experimentally evidenced. Radiation hardening issues are finally discussed as a function of the device geometry and design.