Abstract

PurposeThe phase-domain synchronous machine model has advantages compared to the d/q model, as no transformation of currents is necessary at each time step in a network analysis. The purpose of this paper is to enhance the phase-domain model to calculate the current distribution of the damper bars, including the saturation.Design/methodology/approachThe new enhanced phase-domain model of the synchronous machine has been modelled using Matlab-Simulink. The parameters of the model have been calculated by using FEA software.FindingsIt is shown that the simulation results of the new model show very good accordance to the reference model during a three-phase short circuit.Originality/valueThe enhanced model includes the calculation of the currents in the damper bar and is able to include the harmonics of the inductances.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.