Abstract

We perform a comparative study of hard x-ray emission from femtosecond laser plasmas in 15μm methanol microdroplets and Perspex target. The hard x-ray yield from droplet plasmas is ≃68 times more than that obtained from solid plasmas at 2×1015Wcm−2. A 10ns prepulse at about 5% of the main pulse appears to be essential for hard x-ray generation from droplets. Hot electron temperature of 36keV is measured from the droplets at 8×1014Wcm−2, whereas a three times higher intensity is needed to obtain similar hot electron temperatures from Perspex plasmas. Particle-in-cell simulations with very long scale-length density profiles support experimental observations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.