Abstract

The primary goal of this work was to determine whether artificial receptors that function on the basis of molecular recognition have analytical capabilities. As an example of such a receptor, we have chosen one directed toward barbiturates. Chloroform enriched with this artificial receptor (1 mM) can extract more than 90% of the phenobarbital from a 20 microM phenobarbital solution in human control serum using a volume ratio (organic/serum) as small as 0.5. In the absence of this receptor, the volume ratio must be greater than 10 to achieve similar extraction efficiencies. In addition to volume ratio, the role of pH, receptor concentration, and solvent type are discussed. The experimental results are found to be in good agreement with predictions based on chemical equilibria. Through the use of this and other similar receptors, the amount of organic solvent used in extractions can be minimized.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.