Abstract
To make effective use of model-based control system design techniques, one needs a good model which captures system’s dynamic properties in the range of interest. Here an analytical model of pneumatic muscle actuator with two pneumatic artificial muscles driving a rotational joint is developed. Use of analytical model makes it possible to retain the physical interpretation of the model and the model is validated using open-loop responses. Since it was considered important to design a robust controller based on this model, the effect of changed moment of inertia (as a representation of uncertain parameter) was taken into account and compared with nominal case. To improve the accuracy of the model, these effects are treated as a disturbance modeled using the recurrent (Elman) neural network. Recurrent neural network was preferred over feedforward type due to its better long-term prediction capabilities well suited for simulation use of the model. The results confirm that this method improves the model performance (tested for five of the measured variables: joint angle, muscle pressures, and muscle forces) while retaining its physical interpretation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.