Abstract
Glucose-fed microbial fuel cells (MFCs) have displayed low Coulombic efficiency (CE); one reason for a low CE is metabolite generation, causing significant electron loss within MFC systems. In the present study, notable electron loss (15.83%) is observed in glucose-fed MFCs due to residual propionate, a glucose metabolite. In order to enhance the low CE caused by metabolite generation, a dual-anode MFC (DAMFC) is constructed, which are separately enriched by dissimilar substrates (glucose and propionate, respectively) to effectively utilize both glucose and propionate in one-anode chamber. In the DAMFC, propionate ceases to exist as a source of electron loss, and thus the CE increased from 33±6 to 59±4%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.