Abstract

This paper proposes an enhanced bee swarm optimization method to solve the dynamic economic dispatch problem of thermal units considering the valve-point effects, ramp-rate limits, and the transmission power losses. The bee swarm optimization algorithm unlike most of the population-based algorithms employs different moving patterns to search the feasible solution space. This property makes an effective balance between exploration and exploitation. Different modifications in moving patterns of the bee swarm optimization method are proposed to search the feasible space more effectively. The efficiency of the method is validated using three test systems with 10, 30, and 60 units, including 240, 720, and 1440 design variables. The latter can be considered as a large-scale power system. The results are compared with other reported works in this area and found to be superior.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.