Abstract

To simplify the operation steps of bulk current injection (BCI) instead of high field radiation test and ensure the error is within the controllable range, the analysis and calculation model of the response of the equipment under test (EUT) has been established without a current probe under radiation condition and a current probe under injection condition. The engineeringly equivalent method of bulk current injection replacing high field intensity radiation test is proposed and verified by test. The research results show that the equivalent test error can be controlled within 1dB, which meets the actual requirements of the project.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.