Abstract

AbstractWe study the transport of CO2 molecules inside direct‐air‐capture (DAC) contactors made of packed beds of solid‐sorbent‐particles separated by airgaps using numerical solution of the convection‐diffusion and first‐order adsorption kinetics equations. We quantify an apparent slowdown in the CO2 uptake in such contactors relative to the CO2 uptake of a high‐capacity sorbent particle making the bed. We derive two naturally occurring length‐scales associated with the adsorption process: (1) thickness of the sorbent related to the sorbent chemistry (capacity and adsorption rate constants), packing density, and diffusion coefficient of CO2 inside bed; and (2) extent of the bed in the air‐flow direction related to convective air‐flow velocity, sorbent chemistry, packed bed thickness, and packing density. DAC designs that have a bed thickness of O() and streamwise extent O() are shown to have faster CO2 uptake and more economical capture costs ($/ton‐CO2) compared with designs further away from this design set‐point. Our work should provide guidance to engineering design of DAC contactors with packed bed sorbents and related porous materials.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call