A conducted-susceptibility test procedure based on Bulk Current Injection (BCI) is designed to reproduce similar levels of interference occurring in a standard radiated-susceptibility (RS) test setup for aerospace equipment involving shielded cables. The correlation between test levels is accounted for by an engineering margin called overtesting (OT), which quantifies the excess of interference injected by BCI over RS. Owing to the lack of knowledge about the common-mode impedance of equipment, as well as other setup-related uncertainties, OT turns out to be a random variable, here characterized through its cumulative distribution function. The proposed approach is experimentally validated and complements results developed earlier for unshielded cables. As far as achievement of correlation between BCI and RS tests is concerned, distinctive features of shielded (vs unshielded) cables are shown and discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.