Abstract

For energy-saving control of electrostatic precipitator with multiple electric-field stages, a new optimal control strategy to minimize the total power consumption by adjusting the secondary voltages subject to the dust outlet concentration requirement is suggested. The optimal problem is established on the basis of the proposed mathematical models on the secondary voltage relating to the outlet concentration, the secondary current, the primary voltage and the primary current, and is solved by the genetic algorithm. A practice application to an industrial precipitator is given as well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.