Using two layers of phase change material (PCM) instead of one to improve the thermal energy storage of PCM is a promising way to minimize thermal loads in buildings. This study aimed to maximize the latent heat utilization by splitting the PCM into two layers and adjusting their location and melting temperature. Seven scenarios were created using one or two PCM layers on the inner side, outer side or both sides of an external wall. Energy savings analysis was carried out using a verified numerical model. The results indicated that the monthly optimum PCM melting temperature ranged from 5 °C to 30 °C. Two PCM layers, one on the outside side of the wall with a melting temperature of 17 °C and the other on the interior side with a melting temperature of 25 °C, resulted in higher annual energy savings (17.2%), compared to a single PCM layer (16.8%). With two PCM layers, the energy saving due to latent heat activation increased from 2.5% to 3.2%. Furthermore, this design reduced CO2 emissions by up to 18.4% and caused the surface temperature to approach the comfortable room temperature thereby decreasing thermal loads and improving thermal comfort.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.