Abstract
Thailand is in a tropical region where the global solar radiation often reaches 1000W/m<sup>2</sup> or above with high ambient temperatures and humidity throughout the year. As the sun travels overhead throughout the daytime, heat gain from the roof is significantly pronounced, which consumes intensive amounts of energy from buildings' air conditioning systems. This research focuses on insulated roofs as an energy efficiency measure for stand-alone convenience stores. The resistancecapacitance (RC) model was developed for determining the heat amount from different roof configurations. The model is validated using the measured results: one set from a laboratory chamber and the other set from a selected real store. Based on the annual local weather data, the performance of the insulated roofs is simulated and evaluated against the existing roof. It is evident that the insulated roof can reduce heat gain by 53-68&#37; as compared to the non-insulated roof. The financial analysis also indicates that the insulated roof offers better cost-effectiveness in terms of life cycle cost.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Energy for a Clean Environment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.