Abstract
In this study, the thermal energy performances and environmental effects of two different reinforced concrete structures, Pure Shear Wall (PSW) Building and Shear Wall-Frame (SWF) Building, were investigated in the climatic conditions of Elazig province. Thermal performance analysis for both buildings; was carried out with the TS 825 program. First of all, through this program, monthly and annual heating loads were determined for 11 different alternative building component scenarios of two different buildings. Subsequently, efficiency alternatives were created in accordance with the climatic conditions of the region and TS 825. Efficiency alternatives designed for both buildings have been analyzed together with their completely uninsulated and current states. Finally, buildings with reinforced concrete carrier systems, energy analysis methods and efficiency alternatives were compared and evaluated based on the results of the analysis. As a result, it has been observed that the building with the PSW system consumes more energy than the building with the SWF system when it is uninsulated and in its current condition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.