Abstract
The proton beam energy determines the range of particles and thus where the dose is deposited. According to the depth of tumors, an energy degrader is needed to modulate the proton beam energy in proton therapy facilities based on cyclotrons, because the energy of beam extracted from the cyclotron is fixed. The energy loss was simulated for the graphite degrader used in the beamline at the superconducting cyclotron of 200 MeV in Hefei (SC200). After adjusting the mean excitation energy of the graphite used in the degrader to 76 eV, we observed an accurate match between the simulations and measurements. We also simulated the energy spread of the degraded beam and the transmission of the degrader using theoretical formulae. The results agree well with the Monte Carlo simulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Nuclear Science and Techniques
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.