Abstract

This paper characterised the potential of energy flexibility in relation to building envelop properties, heat emitters and ventilation for the Swedish context. Simulation results indicated that the potential was higher for newer houses with floor heating and lower for older houses with radiators in winter. Older houses with different levels of insulation showed a similar ability of conserving heat due to different extents of heat losses from ventilation. A house with balanced ventilation tended to be over-ventilated especially if the house was not airtight. The flexibility was decreased with increasing outdoor temperatures, and it was higher in winter and lower in spring/autumn.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.