Abstract

The growing attention towards the exergy analysis of thermal systems is identifying the cause of losses, to scale the process, and rectifying the components. In this paper, the thermodynamic (energy-exergy) analysis of combined reheating and regeneration based Rankine Cycle is carried out. The energy-exergy analysis has been established for the boiler, turbines, Feed heaters, condenser and pump majorly. The result of thermodynamic analysis is estimeted in terms of 42% of plant thermal efficiency, 70 % of steam generation unit efficiency (Economizer. Super heater), Maximum heat absorbed by economizer of plant as 39% is achieved, with 40TPH of coal consumption. Boiler, High Pressure Turbine, Intermediate Pressure Turbine, Super Heater have found best performance in analysis and Reheating-Regenerative rankine method improves 6-8% in thermal efficiency also. This analysis concluded that energy efficiency is greater than exergy efficiency which identifies the power plant utilities and further improvement for efficient power generation opportunities like waste heat recovery technology employment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.