Abstract
This article presents an experimental study of the heat transfer characteristics and the pressure drop of the circular tube fitted with multiple short-length taper twisted tape in convergent and divergent mode with the pitch ratios of 3, 4 and 5 and full-length twisted tape of two different pitch length such as 10 and 14 cm. Tapered twisted tapes have a larger effect on the enhancement of heat transfer with the lower pressure drop compared with the short-length uniform width twisted tape. Based on constant pumping power and constant heat duty, short-length taper twisted tapes are performed better than full-length twisted tape. Based on the experimental data, correlations are developed by using the statistical analysis and the arrived results are within the acceptable limit.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.