Abstract
The article considers the method of energy efficiency improvement of 0.4 kV power supply systems for the enterprise located in the North of the Krasnoyarsk territory. The theoretical substantiation of the necessity of reactive power compensation is presented. The method for reducing reactive power in power supply networks through the use of devices compensating reactive power is proposed. The use of this method allowed reducing energy costs, as well as decreasing the level of reactive power in the network by 48.5% and 45% for the 1st and the 2nd inputs, respectively. Also, while using reactive power compensation devices for power supply networks, the following indicators can be achieved: the increase in the throughput capacity of electric networks, the reduction in active power losses and the rational electric energy use.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.