Abstract

Wastewater treatment plants (WWTPs) are considered as energy-intensive industries. A comprehensive assessment of energy efficiency in sewage treatment reveals issues of energy waste, offers insights into the energy consumption structure, fosters optimization of energy management, and enhances overall energy utilization. However, the mathematical modeling for energy efficiency evaluation becomes challenging due to the ambiguity and uncertainty of the parameters regarding energy consumption and various indicators. In this paper, the newly constructed evaluation method was used to quantify the energy efficiency. This method employs dimensional reduction, projecting the numerical values of unit energy consumption for various pollutants onto a lower-dimensional space, and then computing the projected eigenvalues. Larger eigenvalues indicate higher energy efficiency. Based on the evaluation results, the back propagation (BP) neural network is used to simulate the sewage treatment process. The results demonstrated that when the inflow load is small and the concentration of pollutants is high, the energy efficiency of sewage treatment plants performs well. When the inflow load is high and the concentration of pollutants is low, the energy efficiency of sewage treatment plants is poor. Meanwhile, the energy consumption could be decreased by 11.61 %, 14 %, and 15.26 % respectively in different scenarios.