Abstract

The Caltech spheromak experiment uses a size A ignitron in switching a 59-?F capacitor bank (charged up to 8 kV) across an inductive plasma load. Typical power levels in the discharge circuit are ~200 MW for a duration of ~10 ?s. This paper describes the setup of the circuit and the measurements of various impedances in the circuit. The combined impedance of the size A ignitron and the cables was found to be significantly larger than the plasma impedance. This causes the circuit to behave like a current source with low energy transfer efficiency. This behavior is expected to be common with other pulsed plasma experiments of similar size that employ an ignitron switch.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.