Abstract

Four new energy control strategies are proposed here for the Fuel Cell Hybrid Power Source (FCHPS) used in stationary and mobile FC application (such as the FC backup source for a smart-house and FC vehicle, respectively) based on the Load Following (LF) control and Maximum Efficiency Point Tracking (MEPT) control of the fueling rates. The LF control approach is used to design simple strategies of the Energy Management Unit (EMU) that will assure a charge-sustaining mode for the batteries stack of the Energy Storage System (ESS). If a fueling rate is controlled based on the LF strategy, then the other is controlled based on MEPT strategy in order to maximize the FC net power available. The advantages of the proposed EMU strategies during an unknown load cycle are comparatively shown.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.