Abstract

ABSTRACTThe energy and exergy assessments of the dehydrogenation of propane for propene production process were performed. The results show that when the reaction temperature rises from 400°C to 1000°C, the range of inlet and outlet exergy is 2268∼2376 and 2265∼2341 kJ/mol C3H6, respectively, and the range of exergy destruction is 6.31∼33.24, 9.93∼35.15 and 3.59∼31.99 kJ/mol C3H6 at 5, 25 and 45°C reference environment temperature, respectively. The range of exergy efficiency at discussed reference environment and reaction temperature is 98.52∼99.84%, and decreases with the increasing of reaction temperature and increases with the decreasing of reference environment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.