Abstract

This study presents a comparison of energetic and exergetic performance of a vapour compression refrigeration system using pure HC (hydrocarbon) refrigerants. In this study, three different pure HCs propane (R290), butane (R600) and commercial LPG (liquefied petroleum gas) are used in the theoretical analysis. R134a is also used in the analysis as a reference refrigerant. The evaporator temperature ranges from −30 to 0 °C while the condenser ranges from 30 to 50 °C. MATLAB software is used for solving the thermodynamic equations, while the thermo-physical properties are calculated using REFPROP software. The results show that R600 has the highest COPc and exergetic efficiency, while LPG has the lowest. When compared to R134a, the COPc for R134a is higher than that for LPG by 10%. Also, the exergetic efficiency is higher by 5%. However, LPG has the advantage of being not expensive, available in large amounts and zero ozone depletion potential and low global warming potential.