Abstract

In this experimental study, a proportional integral derivative (PID) controlled heat pump dryer was designed and manufactured. Heat pump dryer was tested drying of hazelnut and energy analyses were made. Drying air temperatures were changed as 50,45 and 40°C in the drying system. Drying air velocities were changed as 0.25 m s−1 for 50°C, 0.32 m s−1 for 45°C and 0.38 m s−1 for 40°C. Heating coefficient of performance of whole system (COPws) of the heat pump dryer was calculated as 1.70 for 50°C, 1.58 for 45°C and 1.40 for 40°C drying air temperatures. Energy utilization ratio changed between 24 and 65% for 50°C, 17 and 63% for 45°C and 14 and 43% for 40°C drying air temperatures in the heat pump dryer. Copyright © 2008 John Wiley & Sons, Ltd.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.